Technical Bulletin UTAX
CD 1430
TA DC 2430
TB 05 / Note when replacing the SCANNER WIRE
SB-A184/M
Date: 16-06-2010
T
OPIC
:
WIRE SCANNER BLACK/GRAY (No.1, 2) are changed as below to improve the procurement.
Accordingly, marking to the terminal is changed from black to red.
And, an attention is required when replacing the parts according to this change.
Please refer to Field Measure as below.
Wire type: (Before) EC75-100R2 --> (After) WS77-100
Outer diameter (Before resin coating*): (Before) 0.75mm --> (After) 0.77mm
Strand diameter: (Before) 0.05mm --> (After) 0.07mm
Number of strand: (Before) 133 --> (After) 75
* New outer diameter after resin coating is same as the old one.
M
ARKING TO THE TERMINAL
:
(The marking is applied to the side that faces SHAFT DRIVE when fitting the wire to DRUM PULLEY)
Before After
Q’ty Compatibility
No.
Old Part
No.
New Part
No.
Description
Old New Old New
SP Remarks
1 2C912350 2KK17540 WIRE SCANNER BLACK 1 1
X X -
Machine rear side
2 2C912360 2KK17550 WIRE SCANNER GRAY 1 1
X X -
Machine front side
Parts with “O” indicates regular maintenance parts. The above-mentioned parts are not set as the spare parts in the Parts List.
Classification
Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measure: Please use either set of the new parts (No.1, 2) or the old when replacing the wires.
Serial Nos. of Affected Machine: After using up the old stock.