4-6 Maintenance
Cleaning the Printer
To avoid print quality problems, the interior of the printer must be
cleaned with every toner container replacement.
1 Open the top cover and front cover.
2 Lift the developer unit together with the toner container out of the
printer.
3 Remove the drum unit from the printer by holding the green levers
with both hands.
Developer
Unit
Drum
Unit
Note The drum unit is sensitive to light. Never expose the
drum unit to light for more than five minutes.